Question: Do I Need Tamper Resistant Outlets?

Are tamper resistant GFCI outlets required?

All nonlocking type 15A and 20A, 125V receptacles in the following areas of a dwelling unit [210.52] must be listed as tamper-resistant [406.12].

Exception: Receptacles in the following locations aren’t required to be tamper-resistant: Receptacles located more than 5½ ft above the floor..

How do I know if my outlets are tamper resistant?

How I can tell if a receptacle outlet is tamper resistant?The letters “TR” are embossed between the two vertical slots (hot and neutral).Tamper resistant receptacles use a plastic shutter just inside the two vertical slots, and it will not release unless equal pressure is applied to both of them at the same time by the two prongs of an electrical cord.Jul 22, 2018

Why is there plastic in my outlet?

That is the next generation of receptacles called tamper resistant. It keeps the kids from sticking something into the prongs. You need to push the plug in 100% straight so that both slots open at the same time. They can be a bit of a nuisance.

What makes a GFCI tamper resistant?

Tamper-resistant receptacles contain a shutter mechanism which blocks access to the contacts unless a two or three pronged plug is inserted. When pressure is simultaneously applied to both sides, the receptacle shutter opens to allow the standard plug to make contact with the receptacle contacts.

What is a tamper resistant outlet?

The new tamper-resistant outlets look just like regular outlets but have an interior cover that will open only when the two prongs of a plug are inserted simultaneously. This prevents children from sticking something into one of the slots and getting burned or electrocuted.

What is weather resistant outlet?

Weather resistant receptacles are designed with. nylon and corrosion resistant metal components; when installed in an approved weather protective cover, weather resistant receptacles offer extra durable protection from rain, snow, ice, moisture and humidity.

Why is it so hard to plug into an outlet?

2 Answers. They are tamper resistant, as indicated by the letters “TR” stamped between the holes. The secret is to insert the plug squarely into the receptacle. The two little doors inside have to be pushed at the same time by the prongs of the plug.

Are tamper resistant outlets worth it?

Tamper-resistant outlets reduce the risk of electrical injuries, but they are not completely tamper-proof. Unfortunately, some people believe that tamper-resistant outlets are “child proof” when they are not. Tamper-resistant outlets do not prevent children from imitating adults and inserting plugs into outlets.

When did tamper resistant receptacles become required?

2008Tamper-resistant (TR) receptacles were first required within the 2008 edition of the National Electrical Code (NEC).

Each of the benefits of tamper-resistant outlets ensures your family’s health and safety. Dangers of electrocution drop, along with the risk of electrical fires caused by curious kids. Children may try to stick narrow objects into electrical outlets just to see what happens.

What are two exceptions to the code for tamper resistant receptacles?

Exception to (1) through (7): Receptacles in the following locations aren’t required to be tamper resistant: (1) Receptacles located more than 5½ ft above the floor. (2) Receptacles that are part of a luminaire or appliance.

Where do you have to use tamper resistant outlets?

Tamper Resistant Receptacles are required in new and renovated: Childcare facilities. Hotel and motel guest rooms. Preschools and elementary education facilities….Exceptions:Outlets located more than 5 ½ ft above the floor.Outlets that are part of a luminaire.Outlets dedicated to appliances that cannot be easily moved.Mar 13, 2017