Quick Answer: What Is Code For Outlets In Kitchens?

How far does a GFCI have to be from a kitchen sink?

3 feetIt must be a GFCI, and it must be within 3 feet of the edge of the sink.

Either behind or beside the sink is acceptable — across from the sink on an opposite wall is not..

What type of receptacles are required in the kitchen?

Requirement: Provide at least two 20-amp, 120-volt circuits to supply power to GFCI (Ground Fault Circuit Interrupter) Why: The 20 amps are required (vs. 15 amp) for the higher power requirements found in kitchens. Think toaster ovens, blenders, and mixers.

Do I need 20 amp outlets in kitchen?

Kitchens, by code, are required to have at least two 20 amp, 120-volt circuits to be installed on every kitchen countertop. The main reason for this is so the outlet can handle enough amps to power simple kitchen cookware such as microwave ovens, toasters, and blenders.

Does every outlet in a kitchen need to be GFCI?

Kitchens: All receptacles serving countertop areas and any receptacle within 6 feet of a sink must have GFCI protection. … Laundry, utility, and wet bar sinks: Where receptacles are placed within 6 feet of the outside edge of the sink, they require GFCI protection.

Can you put a refrigerator on a GFCI?

In a dwelling unit (residential), GFCI protection is only required for kitchen receptacles that serve the countertop surfaces. There’s no requirement to GFCI protect receptacles that serve a refrigerator. Unless the fridge is plugged into a countertop receptacle.

Should a refrigerator be on a 20-amp circuit?

Refrigerator Circuit A modern refrigerator requires a dedicated 20-amp, 120/125-volt circuit. You may currently have a smaller refrigerator plugged into a general lighting circuit, but during any major remodeling, a dedicated 120/125-volt circuit for the refrigerator should be installed.

How many outlets can I put on a 20-amp kitchen circuit?

two outletsKitchens must have at least two outlets of 20-amps. The outlets in the kitchen are required to power very high voltage kitchen appliances. A 20-amp circuit is used to power appliances like microwave ovens, toasters, as well as blenders.

What causes nuisance tripping of GFCI?

1. There are too many appliances being protected by the GFCI. Sometimes tripping occurs when a GFCI circuit breaker is protecting multiple downstream receptacles. If several appliances are connected to the GFCI device, the cumulative effect of the appliance leakage currents may trip the GFCI.

How many outlets can be on a 15 amp breaker?

8 outletsTechnically, you can have as many outlets on a 15 amp circuit breaker as you want. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Therefore, we would suggest a maximum of 8 outlets for a 15 amp circuit.

Where should outlets be placed in a kitchen?

Where should you put kitchen outlets?1) Under cabinet plugs. When your backsplash is the special feature of the kitchen (think marble slabs or a tile pattern you don’t want to interrupt), under cabinet plugs will keep it looking uniform. … 2) Color coordinated wall outlets. … 3) Group outlets with switches. … 4) Always add an outlet to your island.Mar 29, 2018

What is the standard height for outlets in a kitchen?

about 43 inchesKitchen receptacles install above the backsplash of counter tops. This makes the correct height about 43 inches from the bottom of the box to the floor.

What is the maximum distance between outlets on a kitchen counter?

In the kitchen, countertop outlets should be no farther than 48 inches away from each other. This spacing is based on the average length of electrical cord found on most small kitchen appliances.

Do kitchens require special outlets?

The National Electrical Code (NEC) requires that kitchens have at least two separate 20-amp, 120-volt circuits for counter-top outlets, which must also be no more than 4 feet apart. If you’re remodeling, consult your electrician and decide where your appliances will go during the planning phase.

How many outlets can I put on a 20-amp breaker?

10 receptaclesOne rule of thumb is to assign a maximum draw of 1.5 amps to each receptacle, which allows for 10 receptacles on a 20-amp circuit.

Can you put 2 GFCI outlets on the same circuit?

There is no need to have a GFCI receptacle as the second receptacle, since it will already be protected by the first GFCI receptacle. … But in a setup like this, you’ll be required to have a GFCI receptacle at both outlets.

How can I hide the outlets in my kitchen backsplash?

Low and Horizontal Outlet Strips If you have countertop space without an upper-cabinet above it, consider placing outlets a little lower than normal, and horizontally, along the very start of your backsplash tile. This placement, combined with well-matched cover plates, will also help your outlets to disappear.

How do I stop my fridge from tripping the GFCI?

If you want to keep the fridge on a GFCI outlet, you can try replacing the breaker in the box with a GFCI breaker. Also, if you’re dealing with a dedicated circuit that just operates the refrigerator in the kitchen, you can simply remove the GFCI outlet and replace with a standard outlet.

Can I plug my fridge into any outlet?

A regular outlet will work. Fridge’s don’t require dedicated circuits (though they should!) A fridge only draws about 6 amps on a standard 110v outlet.

How many outlets can 1 GFCI protect?

There’s no limit. A standard GFCI will protect up to 20 amps, drawn from any combination of receptacles, either the built-in one or any number of additional ones connected to its load terminals.

Should bathroom outlets be 15 or 20-amp?

The minimum requirement for outlet receptacles in a bathroom is one GFCI-protected receptacle served by a 20-amp circuit. This is a bare minimum, however, and most bathrooms will have at least two receptacles, and often as many of four or five.

Should I get a 15 or 20-amp GFCI outlet?

1) You can have a GFI receptacle on either a 15 or 20A circuit. Keep in mind, areas like kitchens, bathrooms, laundry, etc, typically require 20A circuits for receptacles. For areas like outside and garages 20A circuits are always a good idea.